Read the manometer
Most active systems have a U-tube manometer on the pipe. When the fan is pulling suction, the liquid sits higher on one side. If both sides are level, the fan may be off, failed, or disconnected. EPA recommends looking at the warning device on a regular basis.
Listen to the fan
The fan must run continuously for the system to work, so never switch it off. EPA notes that fans may last five years or more. Silence, rattling, or a new loud hum usually means the fan or its mounting needs attention.
Retest on schedule
EPA advises a post-mitigation test no sooner than 24 hours and within 30 days after the system starts running, then retesting at least every two years. Test again after remodeling or if you start using a lower level of the home.
What to send with a repair request
Photos help a provider bring the right parts on the first visit.
- A photo of the manometer showing the liquid levels
- A photo of the fan and its label
- The installation date and installer, if known
- Your most recent radon test result